Reproducibilidad del test Functional Movement Screen en futbolistas aficionados

  • M.L. Alfonso-Mora Facultad de Enfermería y Rehabilitación, Universidad de La Sabana, Chía, Cundinamarca, Colombia
  • L.M. López Rodríguez Universidad de La Sabana, Chía, Cundinamarca, Colombia
  • C.F. Rodríguez Velasco Universidad de La Sabana, Chía, Cundinamarca, Colombia
  • J.A. Romero Mazuera Universidad de La Sabana, Chía, Cundinamarca, Colombia

Resumen

Original
Reproducibilidad del test Functional Movement Screen en futbolistas aficionados
Reproducibility of the test Functional Movement Screen in amateur soccer players
Reprodutibilidade do teste Functional Movement Screen em futebolistas amadores
 
Recibido 16 noviembre 2015, Aceptado 04 julio 2016
Resumen
Objetivo

Tener instrumentos válidos y confiables para tamizar el riesgo de lesión es importante para disminuir la incidencia de lesiones en atletas, por lo cual el objetivo de este estudio fue determinar la reproducibilidad del test Functional Movement Screen en futbolistas aficionados.

Método

Un total de 36 futbolistas aficionados universitarios fueron evaluados. Las pruebas fueron aplicadas por cuatro fisioterapeutas. Los evaluadores calificaron el desempeño en las ocho pruebas físicas del Functional Movement Screen en tiempo real de aplicación de la prueba; para el retest se asistió al campo con una semana de intervalo y se aplicaron nuevamente las ocho pruebas en el 20% de la muestra. Para el cálculo de reproducibilidad intraevaluador se aplicó el índice Kappa de Fleiss, y para la reproducibilidad entre evaluadores se utilizó el intervalo de correlación intraclase.

Resultados

Según el cálculo de la prueba Kappa de Fleiss el test Functional Movement Screen mostró un grado de acuerdo interevaluadores casi perfecto K = 0.89-1; también presentó una estabilidad intraevaluador excelente con un intervalo de correlación intraclase = 0.81.

Conclusión

El test Functional Movement Screen es reproducible como herramienta de tamizaje de riesgo de lesión en futbolistas aficionados.

Abstract
Objective

It is necessary to have valid and reliable test for to screening the risk of injuries in athletes, furthermore the aimed for this study was determined the reproducibility of the Functional Movement Screen in amateur soccer players.

Method

36 university amateur footballers were tested. Four physiotherapists applied the Functional Movement Screen, and Re-test was applied in real time to 20% of participants. To calculate intra rater reproducibility was used index Kappa Fleiss, and for inter-rater was used intraclass correlation interval.

Results

According of Kappa Fleiss Functional Movement Screen test showed a degree of interrater agreement almost perfect K = 0.89 to 1, also exhibited excellent stability intraevaluador intraclass correlation interval = 0.81.

Conclusion

The Functional Movement Screen test is reproducible as a screening tool for risk of injury in amateur footballers.

Resumo
Objetivo

Ter instrumentos válidos e confiáveis para a triagem do risco de lesão é importante para reduzir a incidência de lesões em atletas, de modo que o objetivo deste estudo foi determinar a reprodutibilidade do teste Functional Movement Screen em futebolistas amadores.

Método

36 futebolistas amadores universitários foram avaliados, os testes foram aplicados por quatro fisioterapeutas; os avaliadores classificaram o desempenho nas provas físicas do teste Functional Movement Screen em tempo real de aplicação do teste; para o reteste se assistiua campo com uma semana de intervalo e aplicaram novamente os oito testes para 20% da amostra. Para calcular a reprodutibilidade intra-avaliadores o índice Kappa de Fleiss foi aplicado, e para a reprodutibilidade entre avaliadores foi utilizado o intervalo de correlação intraclasse.

Resultados

De acordo com o cálculo do indice Kappa Fleiss o teste Functional Movement Screen mostrou um grau de concordância entre quase perfeita K = 0.89 para 1, também apresentou uma excelente estabilidade intra-avaliadores pelo intervalo de correlação intraclasse = 0.81.

Conclusão

O teste Functional Movement Screen é reproduzível como uma ferramenta de triagem para risco de lesões em futebolistas amadores.

Palabras clave
Reproducibilidad, Functional Movement Screen, Fútbol, Traumatismo en atletas
Keywords
Reproducibility, Functional Movement Screen, Soccer, Athlete trauma
Palavras-chave
Reprodutibilidade, Functional Movement Screen, Futebol, Trauma em atletas
Publicado
2018-04-23
Sección
Originales
Página/s
74-8